The waterproof detection of smart watches is now well known by various manufacturers in the market.If the smart watch is not tested for air tightness, it will directly affect the service life of the smart watch.Recently, Hirays Technology has received a lot of inquiries from customers about smart watches. What if a smart watch is tested for waterproofing? What is the principle of air tightness testing for smart watches? 5ATMSmart watch waterproof test?8ATM smart watch air tightness testHow to implement it? There are many similar questions like this.Today, Hirays Technology will share with you 5ATM and 8ATMSmart watch waterproof test/气密性测试的测试原理和测试方法。
First, let’s briefly introduce the structure of the smart watch, as well as the 5ATM waterproof and 8ATM waterproof levels of the smart watch.The waterproofing of watches depends on the waterproof rubber rings on the watch mirror, back cover, handle, etc. to meet the corresponding standards. All waterproof watches are stamped on the bottom cover.“WATERRESISTANT or“WATERPROOF” in English.Watches without a waterproof mark are only dustproof and should be kept away from water.
5ATM waterproofing: It requires that the waterproofing of the component must meet the atmospheric pressure waterproofing level of 5ATM. It does not mean that it can dive 50 meters under the sea without water entering.
The 5ATM waterproof watch can be used for swimming in shallow water areas and general hand washing.8ATM can be suitable for swimming and underwater work.
If the customer wants to test 5ATM, its waterproof level is equivalent to IP68.When testing the waterproof performance of watches, manufacturers generally choose the air tightness testing method and use compressed air to test the waterproof performance of watches.If tested with water, watch movements that do not reach the waterproof level will be easily damaged by water and scrapped.

Figure: 5ATMMSmart watch waterproof detection
The waterproof level that Hirays received from the customer this time for testing is 5ATM, and the customer requested a pressure of 500KPA for testing.Judging from the appearance of the customer's product, the appearance of the watch is artificial sapphire. From the material evaluation, the product should be able to withstand the pressure of 500KPA.If the product is a plastic product or an ordinary glass product, the product cannot withstand too much pressure, and setting too much pressure will cause damage to the product.According to the customer's testing requirements, the parameter values we set for the customer are the air intake time of 5S, the voltage stabilization time of 5S, and the test time of 5S. The total time to complete the test is 15S.
Since the product is relatively small and does not have any inflation holes, we need to use indirect testing through the mold to test.When customizing a test plan for a customer, it is necessary to make a completely sealed mold for the customer based on the customer's product hot spots and appearance. Whether the sealing degree of the mold is sufficient directly affects the test results. This step is very important.
After the fixture and mold are completed, the tooling can be connected to our air tightness detector through the air pipe.After setting up the test data, you can start testing the product.If the product is defective, the air tightness test will automatically alarm to remind the tester.

Picture: Hirays HC classic series air tightness tester
The instrument chosen for the air tightness test of smart watches this time is our HC classic series air tightness tester. The HC classic series air tightness tester is a very mature and stable instrument from Hirays.With its high precision and stability, more than 1,000 sets of equipment have been deployed in more than 400 customer factories.The functions and performance parameters of the instrument can meet the needs of most customers while also taking into account the cost-effectiveness. It can meet the waterproof test/air tightness test of different smart watches. The following is a collection of our cases for waterproof testing of smart watches:

-
2026.04.11Good News | Hirays Honored as "Most Investment-Worthy Enterprise" at 2026 AI Glasses China Tour
-
2026.04.11Why are more and more companies opting for RGA technology for power bank electrolyte leakage detection?
-
2026.03.30Commemorating the revolutionary martyrs and inheriting the red spirit | Record of hirays’s theme activity of walking to commemorate the martyrs’ cemetery
-
2026.03.20Starting from June, the sale of non-compliant power banks will be banned: many companies ignore this detection issue
-
2026.03.16After charging 70% in 5 minutes, how can the safety of the power battery be maintained?
-
2026.03.14Overcoming difficulties and showing responsibility, efficient delivery wins praise - a tribute to the four pioneer employees on the production front line
-
2026.03.03Comparison of mass spectrometry technology applications: How do Heris helium mass spectrometers and RGA series enable precision manufacturing?
-
2026.02.26Construction has started | hirays starts a new journey of struggle in 2026
-
2026.02.06Let’s work together to embark on a new journey | The 3rd hirays Fun Games was successfully held