As we all know, as a container for storing liquid, a water storage bag has very high air tightness requirements. If its sealing degree is not high, the entire water storage bag will be unqualified and cannot be used normally.In order to ensure its air tightness, the manufacturer will conduct an air tightness test on it. Hirays has developed a special air tightness tester for the detection of water storage bags and put it into the production line.This time we will share the air tightness test case of the water storage bag, hoping to give everyone a reference.

Water storage bag air tightness tester
1. Display of the appearance and detection difficulties of water storage bags
The water storage bag has a high degree of sealing and is made of high-precision materials. There is a water outlet pipe in the middle of the water storage bag. The water storage bag has a high degree of folding. During testing, it must not only meet its sealing and non-destructive requirements, but also ensure that the test results are accurate.

Water storage bag
2. Demonstration of the air tightness test process of water storage bags
1. Since the overall sealing degree of the water storage bag is high and the only air outlet is the middle pipe, then just align the middle pipe opening of the water storage bag with the air outlet of the connected instrument and fix it before testing.


Details of air tightness testing tooling for water storage bags
2. When the test starts, put the water storage bag into the tooling, fix it through the nozzle, and connect it to our instrument. There is a valve island, gas storage tank and other components inside the instrument as well as the program we have set.
3. After connecting, press the start button.The upper and lower molds behind the water storage bag tube are closed to fix the mouth of the water storage bag. The device connected to the conduit on the left side of the tooling will fill the inside of the water storage bag with impurity-free gas, so that the air tightness of the water storage bag can be judged by the saturation of the air inside the water storage bag;

Air tightness testing tool for water storage bags
4. If the water storage bag is not sealed and air leakage occurs, the leakage value displayed in the instrument will become larger and larger, and the pressure value will decrease at the same time.At this time, you can determine whether the water storage bag is leaking, and the instrument test result will also show NG, which means the air tightness test failed.If the tested water storage bag does not leak, the gas in the tooling mold will be in a constant state after inflation. The pressure value and leakage value displayed on the instrument are also stable. The instrument test result will display OK, indicating that the air tightness test has passed.
3. Air tightness tester parameters of water storage bag

The copyright belongs to Hirays Technology. Reprinting and counterfeit originality are prohibited. Any violation will be at your own risk.
-
2026.11.13Hirays Completes Delivery of a Major RGA Project for a Leading New Energy Customer
-
2026.11.13Hirays Named a National-Level "Little Giant" Enterprise
-
2026.11.13Media Coverage | Precision Testing Sector Gains Fresh Capital Backing: Hirays Technology Completes Series B Financing
-
2026.11.06Joining Forces, Starting Anew, Winning the Future Together | HIRAYS Marks 18 Years with a Team-Building Journey in Qingyuan
-
2026.11.06HIRAYS Shares RGA Quadrupole Mass Spectrometry Leak-Detection Expertise at CQC Compliance Training in Shenzhen
-
2026.11.06Leaders of CQC Shenzhen Branch Visit HIRAYS for Inspection and Guidance, Discuss Quality Improvement and Technological Innovation
-
2026.11.04The Full Hirays HM Mass Spectrometry Portfolio in One Place: One-Stop Protection for High-End Precision Manufacturing
-
2026.11.04HM-230 RGA: In-Situ Gas Monitoring Across Multiple Pressure Regimes
-
2026.11.04A New Frontline Defense for Line Yield: Hirays' HM-150 RGA Stands Up to Harsh Process Conditions to Protect Every Wafer



