What are the requirements for IP65 waterproof testing of smart watches? What are the test conditions for IP waterproof level? How to use the Hirays air tightness tester to test!
In daily life, smart watches are soaked by water all the time, so the waterproof detection of smart watches is very important. Most manufacturers currently use IP65 waterproof grade, IP66, and IP67 waterproof grade.
As people's demands for living materials are getting higher and higher, smart wearable devices are favored by the majority of people. Technically, smart watches are already relatively mature wearable products. According to surveys, global smart watch shipments will account for 87% of smart wearables in the next two years. This is also reflected in theIn response to the development prospects of smart watches, smart watches have great advantages in the market. When a product is put on the market, it needs to be tested for a certain IP waterproof level. Only when the product is sold on the market can it be said that it is a qualified product and can be sold normally in the market.

IP6x dust proof test
Put the smart hand in the waterproof testing tool, and then set the test parameters of the IP waterproof tester. You can start the tester for detection, and then determine the IP65 waterproof level based on the air leakage.
Smart watch waterproof rating IP test:
(1) IPX5 method name: Water spray test Test equipment: The inner diameter of the water spray port of the nozzle is 6.3mm; Sample placement: Make the distance between the test sample and the water spray port 2.5~3m, and the water flow rate is 12.5L/min (750 L/h); Test time: Calculated based on the surface area of the shell of the sample being tested, 1 minute per square meter (excluding the installation area) is less than 3 minutes.
(2) IPX6 method name: Strong water spray test; Test equipment: The inner diameter of the water spray port of the nozzle is 12.5 mm; See Chapter 2.14 of this book for device graphics and test methods; Test conditions: Make the distance between the test sample and the water spray port 2.5~3m, and the water flow rate is 100 L/min (6000 L/h); Test time: Calculated based on the surface area of the tested sample shell, 1 min per square meter (excluding installation area) less than 3 min.
(3) IPX7 method name: short-time immersion test; test equipment and test conditions: immersion box.The size should be such that after the sample is placed in the immersion box, the distance from the bottom of the sample to the water surface is at least 1m.The distance from the top of the specimen to the water surface should be at least 0.15 m.Test time: 30 minutes.
(4) IPX8 method name: continuous diving test; test equipment, test conditions and test time: determined according to the standard and the product to be tested. Its severity is higher than IPX7.Acceptance conditions: The allowable amount of water ingress and details of the withstand voltage test should be specified.Generally speaking, if water enters, it should not be enough to affect the normal operation of the equipment or undermine safety. Water should not accumulate on insulating parts that may cause leakage and traces along the creepage distance. Water should not enter live parts, or enter and hinder operation in a wet state. Water should not accumulate near the cable head or enter the cable.

Hirays Air Tightness Tester is an instrument that can test IP waterproof level. It has more than ten years of rich experience in the field of product testing and non-standard on-demand customization. It is an automation equipment technology enterprise that integrates IP waterproof level testing, air tightness testing, sealing testing, leakage testing, and non-standard customization.Professional waterproof testing, sealing testing, and air tightness testing instruments for various products, with strong versatility, especially authoritative for IP6566 67 68 waterproof level testing of smart watches.