Infrared probes, also called IR probes, can be widely used to measure suspended solids concentration, sludge concentration and turbidity values. They can also be used in mixed solutions, final discharged suspended solids and sludge interface detection, and can also be used as ordinary lenses.

If it is used to detect the sludge interface height in the sedimentation tank, the sealing and waterproofness of the infrared probe must be ensured to ensure the normal operation of the probe.
What I’m sharing today is aboutInfrared probe air tightness testcase.
Testing instrument: HC classic seriesAir tightness detector

Detection method: Customize the dual-channel jig and tooling according to the structure of the probe and customer needs.

Using positive pressure and indirect testing methods, place the product to be tested into the mold, press the start button of the tooling, and start testing.Inflation 15.5Kpa, inflation time 10s, pressure stabilization time 10s, test time 5s, quantitative air intake 6s, leakage upper limit 100pa.During the test, if the leakage value exceeds the set value, the product to be tested is a defective product, otherwise it is a qualified product.
Haris air tightness testing equipment income:
A. Ensure the stability of the mold;
B. High resolution, no matter how small the leakage is, it can be accurately detected;
C. Experienced engineers bring sophisticated mold design, so that every set of molds you use is stable and reliable;
D. Instant communication with Haireisi can save you the pain of looking for contacts everywhere;
E. Strict requirements bring a stable detection system to help you select defective products.