Speaking of air conditioning compressors, I believe everyone is familiar with them. Air conditioning compressors play a role in compressing and driving the refrigerant in the air conditioning refrigerant circuit. The air conditioning compressor extracts refrigerant from the low-pressure area, compresses it, and sends it to the high-pressure area for cooling and condensation. It releases heat into the air through heat dissipation fins, and the refrigerant also changes from a gaseous state to a liquid state, increasing the pressure. The air conditioning compressor continuously works, absorbing heat from one end of the low-pressure area into the refrigerant and then sending it to the high-pressure area to dissipate into the air, playing a role in regulating the temperature.

Product to be tested: Air conditioning compressor

 

someThe lack of waterproof measures for the compressor in the air conditioning equipment has caused water to enter the electrical junction box on the compressor, resulting in electrical short circuits and corrosion of the compressor housing. Therefore, improvement is needed.Is there any way to ensurecompressorCan be effectivePerform waterproofing,still canPrevent the electrical box and housing of the compressor from being corroded and damaged, and extend its service lifeWhat about it?

Air conditioning compressor air tightness testing mold

 

Waterproof testing is a good method that can meet the above two situations. Below, Hai Rui Si Technology will share with you a case study on the airtightness and waterproof testing of air conditioning compressors, based on customer requirementsIP67waterproof ratingTesting, the following are the equipment and testing methods used:

Air conditioning compressor airtightness waterproof testing fixture

 

Equipment used: Hai Rui SiHCClassic series dual channel airtight waterproof testing equipment

Testing method: Direct testing method, customize a mold based on the structure of the air conditioning compressor to seal the product, and inflate the interior of the product from the lower mold. test pressure10KPAInflation time8SVoltage stabilization time10STesting time5S.

The customer is very satisfied with the results this time,Quickly detect the overall sealing of the air conditioning compressorAnd the accuracy has increased.

Hai RuisiHCClassic series dual channel airtight waterproof testing equipment

 